SolaX T-BAT BMS unit TBMS-MCS0800

711,00  incl. VAT

The SolaX TBMS-MCS0800 is the main high-voltage battery management unit for the T-BAT-SYS-HV-S2.5 and T-BAT-SYS-HV-S3.6 ranges. It controls charging and discharging of TP-HS25 or TP-HS36 modules, monitors system status, applies protection functions and provides CAN 2.0 / RS485 communication with a compatible SolaX inverter.

Warranty: 10 years as a T-BAT-SYS-HV-S2.5 / S3.6 system component, subject to the manufacturer's warranty terms

PRODUCT CODE: SEBSOLMC080001 CATEGORIES: ,

28 in stock

Description

Purpose

The TBMS-MCS0800 is the main control unit for the T-BAT S2.5 and S3.6 battery systems. It is not a stand-alone energy storage device and has no kWh capacity of its own; energy is stored in the connected TP-HS25 or TP-HS36 battery modules.

Battery management and protection

The unit monitors system voltage, current, temperature and state of charge, controls charging and discharging, and applies battery-system protection functions. Maximum system charging and discharging current can reach 50 A, although the actual value depends on module configuration, temperature and battery state of charge.

Communication and maintenance

CAN 2.0 / RS485 links the battery to a compatible SolaX inverter for remote diagnostics and maintenance.

Installation and configuration

The unit is installed at the top of the battery tower. Depending on the selected battery range and compatible inverter, a complete system can use 2–13 TP-HS25 or TP-HS36 modules. The mechanical battery base and, where required, the series box are separate system components.

Product type: Main high-voltage battery management unit (BMS)

System ranges: SolaX T-BAT-SYS-HV-S2.5 and T-BAT-SYS-HV-S3.6

Model: TBMS-MCS0800

Purpose: Management and protection of battery modules

Compatible battery modules: TP-HS25 (2.5 kWh) and TP-HS36 (3.6 kWh)

Number of modules in the system: 2–13, subject to an approved configuration and inverter compatibility

Energy capacity: Not applicable; the unit does not store energy

Recommended system current: 30 A with TP-HS25; 35 A with TP-HS36

Maximum system charge / discharge current: Up to 50 A; the actual value depends on configuration, temperature and battery state of charge

Communication: CAN 2.0 / RS485

Management functions: Charge and discharge control, status monitoring and system protection

Remote functions: Fault diagnosis, firmware upgrades and maintenance via a compatible inverter

Installation position: At the top of the battery tower

Dimensions (W × H × D): 510 × 157 × 365 mm

Net weight: 13 ±0.5 kg

Base / stand: Separate mechanical component, not included

Complete-system ingress protection: IP65

Complete-system charging temperature: −30 to +53°C with heating; 0 to +53°C without heating

Complete-system discharging temperature: −30 to +53°C with heating; −20 to +53°C without heating

Relative humidity: 4–100% RH (condensation permitted)

Maximum operating altitude: 3,000 m

System certifications and standards: IEC 62619, IEC 60730, IEC 62040, CE, UN38.3